Persona: González Crevillén, Agustín
Cargando...
Dirección de correo electrónico
ORCID
0000-0002-4470-6502
Fecha de nacimiento
Proyectos de investigación
Unidades organizativas
Puesto de trabajo
Apellidos
González Crevillén
Nombre de pila
Agustín
Nombre
19 resultados
Resultados de la búsqueda
Mostrando 1 - 10 de 19
Publicación Untargeted authentication of fruit juices based on electrochemical fingerprints combined with chemometrics. Adulteration of orange juice as case of study(ELSEVIER, 2024) Monago Maraña, Olga; Zapardiel Palenzuela, Antonio; González Crevillén, AgustínThis work presents a novel strategy for authentication of fruit juices. The methodology is based on an electrochemical method combined with chemometrics. In addition, the case of orange juice adulteration with grapefruit juices was studied using this methodology. The electrochemical fingerprint of different juices showed the influence from different polyphenols according to the type of fruit. First, Principal Component Analysis (PCA) was able to differentiate clusters of different juices, being the higher group distance within apple, orange, and grape juices samples. On the other hand, partial least-squares – discriminant analysis (PLS-DA) and PCA-linear discriminant analysis (LDA) were used as classification methods, obtaining better results for orange and apple models. Furthermore, good results were obtained for the authentication of orange juices, compared to other juices, with an error rate of 0.04 for cross-validation. In the case of adulteration of orange juice was detected using PLS-DA at an adulteration level as low as 1%. Regression vectors for all models highlighted identifiable potential values that could be related to the main polyphenols in each type of fruit. This electrochemical method is rapid, low-cost, and compatible with on-site analysis compared to other laborious analysis described in the literature.Publicación Preclinical Validation of an Electrochemical Sensor for Alcohol Consumption Monitoring in a Polydrug Self-Administration Animal Model(MDPI, 2025-03-08) Garrido Matilla, Lucía; María Hormigos, Roberto; Monago Maraña, Olga; Marcos, Alberto; Ambrosio Flores, Emilio; González Crevillén, AgustínAn electrochemical sensor for identification and monitoring of alcoholism was preclinically validated by analyzing plasma from polydrug-consuming rats (alcohol and cocaine). The sensor measures by adsorptive transfer square wave voltammetry the glycosylation level of transferrin, which is an alcoholism biomarker, through a recently reported parameter called the electrochemical index of glycosylation (EIG). Three rat groups were designed: saline group, cocaine group, and cocaine–alcohol group. Moreover, two periods of withdrawal were studied, after 2 days and 30 days. The alcohol–cocaine group after 2 days of withdrawal showed significantly lower EIG values (p < 0.1) than the rest of groups and also alcohol–cocaine group after 30 days of withdrawal, so the sensor was able to identify the alcohol consumption in rats and to monitor the recovery of glycosylation level after 30 days of withdrawal, even combined with cocaine. Furthermore, the effect of sex was also considered. Receiver operating characteristic (ROC) curves were developed for each sex and the corresponding cut-off values were determined. The sensor showed a clinical sensitivity of 70% for male and 75% for female, and a specificity of 67% for both sexes. This preclinical validation demonstrated the possibilities of this sensor for point of care testing of alcoholism, even in cocaine addicts, making it a potential tool for diagnosis and monitoring of alcohol consumption in detox treatments for humans.Publicación A dual colorimetric-electrochemical microfluidic paper-based analytical device for point-of-care testing of ischemic strokes(The Royal Society of Chemistry, 2024-07-29) Dortez, Silvia; Pacheco, Marta; Gasull, Teresa; González Crevillén, Agustín; Escarpa, AlbertoA novel microfluidic paper-based analytical device with dual colorimetric and electrochemical detection (dual μPAD) was developed for the assessment of transferrin saturation (TSAT) in samples from ischemic stroke patients. TSAT was calculated from the ratio between transferrin-bound iron, which was colorimetrically measured, and the total iron-binding capacity, which was electrochemically measured. To this end, a μPAD was smartly designed, which integrated both colorimetric and electrochemical detection reservoirs, communicating via a microchannel acting as a chemical reactor, and with preloading/storing capabilities (reagent-free device). This approach allowed the dual and simultaneous determination of both parameters, providing an improvement in the reliability of the results due to an independent signal principle and processing. The μPADs were validated by analyzing a certified reference material, showing excellent accuracy (Er ≤ 5%) and precision (RSD ≤ 2%). Then they were applied to the analysis of diagnosed serum samples from ischemic stroke patients. The results were compared to those provided by a free-interference method (urea-PAGE). Impressively, both methods exhibited a good correlation (r = 0.96, p < 0.05) and no significant differences were found between them (slope 1.0 ± 0.1 and the intercept 1 ± 4, p < 0.05), demonstrating the excellent accuracy of our approach during the analysis of complex samples from ischemic stroke patients, using just 90 μL of clinical samples and taking less than 90 min in comparison with the 18 hours required by the urea-PAGE approach. The developed fully integrated colorimetric-electrochemical μPAD is a promising ready to use reagent-free device for the point-of-care testing of TSAT, which can be used to assist physicians in the fast diagnosis and prognosis of ischemic strokes, where the decision-time is crucial for the patient's survival.Publicación Cost-effective fully 3D-printed on-drop electrochemical sensor based on carbon black/polylactic acid: a comparative study with screen-printed sensors in food analysis(Springer, 2024) Monago Maraña, Olga; Aouladtayib-Boulakjar, Nadia; Zapardiel Palenzuela, Antonio; García Domínguez, Amabel; Ayllón Pérez, Jorge; Rodríguez Prieto, Álvaro; Claver Gil, Juan; Camacho López, Ana María; González Crevillén, Agustín3D-printing technology allows scientist to fabricate easily electrochemical sensors. Until now, these sensors were designed employing a large amount of material, which increases the cost and decreases manufacturing throughput. In this work, a low-cost 3D-printed on-drop electrochemical sensor (3D-PES) was fully manufactured by fused filament fabrication, minimizing the number of printing layers. Carbon black/polylactic acid filament was employed, and the design and several printing parameters were optimized to yield the maximum electroanalytical performance using the minimal amount of material. Print speed and extrusion width showed a critical influence on the electroanalytical performance of 3D-PES. Under optimized conditions, the fabrication procedure offered excellent reproducibility (RSD 1.3% in working electrode diameter), speed (< 3 min/unit), and costs (< 0.01 $ in material cost). The 3D-PES was successfully applied to the determination of phloridzin in apple juice. The analytical performance of 3D-PES was compared with an equivalent commercial on-drop screen-printed electrode, yielding similar precision and accuracy but lower sensitivity. However, 3D-PES provides interesting features such as recyclability, biodegradability, low-cost, and the possibility of being manufactured near the point of need, some of which meets several demands of Green Chemistry. This cost-effective printing approach is a green and promising alternative for manufacturing disposable and portable electroanalytical devices, opening new possibilities not only in on-site food analysis but also in point-of-care testing.Publicación Transferrin analysis in wistar rats plasma: Towards an electrochemical point-of-care approach for the screening of alcohol abuse(Elsevier, 2022-06-29) Rodriguez-Hidalgo, Gema; Sierra, Tania; Dortez, Silvia; Marcos, Alberto; Ambrosio, Emilio; González Crevillén, Agustín; Escarpa, AlbertoSimple and low-cost point-of-care testing (POCT) approaches are necessary not only for the diagnosis of alcohol abuse but also for the follow-up of patients during the treatment of alcohol dependence. To advance the development towards these approaches, a disposable screen printed-based electrochemical sensor is proposed for the diagnosis of chronic alcohol abuse. The selected biomarker to be screened (and followed up) was the carbohydrate deficient transferrin (CDT), which was assessed using the parameter “Electrochemical index of glycosylation” (EIG). EIG is defined as the ratio between the signal generated by carbohydrates present in transferrin (Tf) (selectively labeled with an Os(VI) tag) and the signal generated by the electroactive amino acids present in Tf, measured by adsorptive transfer square wave voltammetry (AdTSWV). The electrochemical sensor exhibited a good limit of detection (LOD ≤ 0.7 g L−1) well below the normal range of transferrin in serum (ranging from 2 to 3.6 g L−1). In addition, the diagnostic capabilities of the sensor were evaluated in plasma rats from 31 individuals (16 chronically exposed to alcohol and 15 saline control), yielding a very good clinical sensitivity and specificity (81% and 87%, respectively). These results draw the potential of this approach to be used for POCT of alcohol abuse, making it a useful tool to help therapists/clinicians even patient’s family in the follow-up of alcohol rehabilitation.Publicación Electroanalytical paper-based device for reliable detection and quantification of sugars in milk(Elsevier, 2024-01-01) Dortez, Silvia; González Crevillén, Agustín; Escarpa, Alberto; Cinti, StefanoKnowing the level of sugars in food and beverages is essential because they are related to diseases such as diabetes, and obesity, among others. In this regard, an approach has been designed, characterized, and applied to develop the first all-in-one paper-based microfluidic analytical device for the quantification of sugars in milk samples. In particular, the powerful combination of the paper-based platform, the facile manufacturing, and the on-demand customization, allowed to obtain a stand-alone platform that was capable to store all the reagents necessary for the assay, to treating the sample by removing major interferences due to lipids and proteins, and to visualize the results in minutes. A wax-patterned chromatographic paper was finely designed to provide a reagent-free platform for the use of non-specialists applied towards the analysis of sugars' content (lactose as the main sugar). Sugars were electrochemically quantified down to 0.16 g L−1 with a repeatability of 5%. To strengthen the efficacy of the novel platform, the electrochemical paper-based analytical device has been applied to commercial milk, including skimmed, semi-skimmed, whole, and lactose-free, confirming satisfactory performance with analytical reliability. This paper-based architecture opens novel avenues for portable (bio)sensing of other relevant species, not only in the agri-food field.Publicación Integrated calibration and serum iron in situ analysis into an array microfluidic paper-based analytical device with smartphone readout(Elsevier, 2023-09-07) Dortez, Silvia; González Crevillén, Agustín; Escarpa, AlbertoIn this work, a colorimetric microfluidic paper-based analytical device (μPAD) combined with a smartphone readout was proposed for the determination of serum iron (Fe3+), which is linked to transferrin. Firstly, Fe3+ was selectively isolated and preconcentrated from serum by using anti-transferrin immunomagnetic beads (anti-Tf-MBs). Secondly, Fe3+ is reduced to Fe2+ by a hydroxylamine solution (pH 4.8) and then measured in the μPAD, which contains the colorimetric reagent ferrozine. Finally, the intensity of the purple color formed in the μPAD was measured by a smartphone. The approach exhibited an excellent linear correlation (r = 0.996) and good limit of detection (0.3 μg mL−1). Moreover, a certified reference material (human serum) was analyzed by this approach, showing an excellent accuracy (Er < 4%) and inter-device reproducibility (RSD = 1%, n = 3). Interestingly, the μPAD array-design allowed the simultaneous analysis of different samples, improving the sample throughput (up to 5 samples in 130 min, using 100 μL each), and the integration of calibration and analysis into the same device, simplifying the analysis without losing accuracy or sensitivity, and avoiding inter-device variability, which constituted an added value to this approach. These disposable μPADs meet several requirements of point-of-care testing (POCT) because it is cheap, portable, easy-to-use, sensitive, and specific. Therefore, it may be an interesting way for measuring patients’ serum iron levels in situ with reliability, especially, in developing countries, where the prevalence of iron deficiency and iron-deficiency anemia is higher and there are lower health resources than in developed countries.Publicación Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients(ACS, 2023-07-23) Dortez, Silvia; DeGregorio-Rocasolano, Núria; Millán, Mònica; Gasull, Teresa; González Crevillén, Agustín; Escarpa, AlbertoFor the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (Er < 4%) and good precision (RSD ≤ 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited.Publicación Wearable sensor for solar ultraviolet A radiation monitoring based on a basic bismuth nitrate / graphene quantum dots composite(Elsevier, 2025-11-26) María Hormigos, Roberto; Monago Maraña, Olga; Zapardiel Palenzuela, Antonio; González Crevillén, Agustín; Universidad Nacional de Educación a Distancia (UNED)/SantanderUltraviolet A (UV-A) radiation from the Sun is a significant risk factor for skin cancer owing to long-term exposition for outdoor workers. The growing need for wearable health monitoring devices demands real-time UV-A sensors with high analytical performance to avoid skin conditions resulting from prolonged UV-A exposure. In this work, we aimed to develop a novel, power-less, low-cost, long-term-stable, and flexible wearable sensor. Such a sensor is based on basic bismuth nitrate (BBN) covered with graphene quantum dots (GQDs) as a photodetector. BBN@GQD photoelectrical material was produced by a very low-cost pyrolytic procedure in gram-scale quantities on a simple hot plate. GQDs improved photoelectrical activity of BBN, yielding good responsivity of 0.25 mA·W−1 (at 0 V bias, incident light intensity 17 μW·cm−2 and 365 nm wavelength). The combination of BBN@GQD and ITO electrodes provided a very sensitive and selective photodetector (a limit of detection of 1.6 ± 0.6 μW·cm−2 light intensity at 0 V bias for 365 nm UV-A wavelength), better than most current UV-A photodetectors. Its high sensitivity at 0 V bias enables its employment as a functional power-free real-time UV-A monitor device. Moreover, the wearable sensor showed acceptable reproducibility (18.9 % relative standard deviation at 12.5 μW·cm−2 light intensity) and long-term stability (up to 1 month of storage). This work proposes a promising wearable device for UV-A monitoring in an outdoor environment, using a new photosensitive material (BBN@GQD), which offers new opportunities in the development of UV photodetectors.Publicación 3D-Printed SARS-CoV-2 RNA Genosensing Microfluidic System(Wiley, 2022-02-05) González Crevillén, Agustín; Mayorga-Martinez, Carmen C.; Vaghasiya, Jayraj V.; Martin PumeraAdditive manufacturing technology, referred as 3D printing technology, is a growing research field with broad applications from nanosensors fabrication to 3D printing of buildings. Nowadays, the world is dealing with a pandemic and requires the use of simple sensing systems. Here, the strengths of fast screening by a lab-on-a-chip device through electrochemical detection using 3D printing technology for SARS-CoV-2 sensing are combined. This system comprises a PDMS microfluidic channel integrated with an electrochemical cell fully 3D-printed by a 3D printing pen (3D-PP). The 3D-PP genosensor is modified with an ssDNA probe that targeted the N gene sequence of SARS-CoV-2. The sensing mechanism relies on the electro-oxidation of adenines present in ssDNA when in contact with SARS-CoV-2 RNA. The hybridization between ssDNA and target RNA takes a place and ssDNA is desorbed from the genosensor surface, causing a decrease of the sensor signal. The developed SARS-CoV-2/3D-PP genosensor shows high sensitivity and fast response.