Publicación: Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients
| dc.contributor.author | Dortez, Silvia | |
| dc.contributor.author | DeGregorio-Rocasolano, Núria | |
| dc.contributor.author | Millán, Mònica | |
| dc.contributor.author | Gasull, Teresa | |
| dc.contributor.author | González Crevillén, Agustín | |
| dc.contributor.author | Escarpa, Alberto | |
| dc.date.accessioned | 2025-10-21T11:05:42Z | |
| dc.date.available | 2025-10-21T11:05:42Z | |
| dc.date.issued | 2023-07-23 | |
| dc.description | The registered version of this article, first published in “Analytical Chemistry 2023, 95, 33, 12391–12397", is available online at the publisher's website: ACS, https://doi.org/10.1021/acs.analchem.3c01982 La versión registrada de este artículo, publicado por primera vez en “Analytical Chemistry 2023, 95, 33, 12391–12390", está disponible en línea en el sitio web del editor: ACS, https://doi.org/10.1021/acs.analchem.3c01982 | |
| dc.description.abstract | For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (Er < 4%) and good precision (RSD ≤ 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited. | en |
| dc.description.version | versión publicada | |
| dc.identifier.citation | Dortez, S., DeGregorio-Rocasolano, N., Millán, M., GasullAgustín, T., G. Crevillen, A., Escarpa, A.(2023).Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients. Analytical Chemistry 2023, 95, 33, 12391–12397. https://doi.org/10.1021/acs.analchem.3c01982 | |
| dc.identifier.doi | https://doi.org/10.1021/acs.analchem.3c01982 | |
| dc.identifier.issn | eISSN: 1520-6882 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14468/30549 | |
| dc.journal.issue | 33 | |
| dc.journal.title | Analytical Chemistry | |
| dc.journal.volume | 95 | |
| dc.language.iso | en | |
| dc.page.final | 12397 | |
| dc.page.initial | 12391 | |
| dc.publisher | ACS | |
| dc.relation.center | Facultad de Ciencias | |
| dc.relation.department | Ciencias Analíticas | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.uri | http://creativecommons.org/licenses/by-sa/4.0/deed.es | |
| dc.subject | 2301 Química analítica | |
| dc.subject | 2306 Química orgánica | |
| dc.subject.keywords | Color | en |
| dc.subject.keywords | Colorimetry | en |
| dc.subject.keywords | Iron Serum | en |
| dc.subject.keywords | Testing and assessment | en |
| dc.title | Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients | en |
| dc.type | artículo | es |
| dc.type | journal article | en |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 0f39284a-d95a-443a-bb2e-21297ec40b76 | |
| relation.isAuthorOfPublication.latestForDiscovery | 0f39284a-d95a-443a-bb2e-21297ec40b76 |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Gonzalez_Crevillen_agustin_Paper_based analyt_AGUSTIN GONZALEZ CRE.pdf
- Tamaño:
- 2.79 MB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 3.62 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: