Fecha
2025-03-08
Editor/a
Director/a
Tutor/a
Coordinador/a
Prologuista
Revisor/a
Ilustrador/a
Derechos de acceso
info:eu-repo/semantics/openAccess
Título de la revista
ISSN de la revista
Título del volumen
Editorial
MDPI

Citas

0 citas en WOS
0 citas en
Proyectos de investigación
Unidades organizativas
Número de la revista
Resumen
An electrochemical sensor for identification and monitoring of alcoholism was preclinically validated by analyzing plasma from polydrug-consuming rats (alcohol and cocaine). The sensor measures by adsorptive transfer square wave voltammetry the glycosylation level of transferrin, which is an alcoholism biomarker, through a recently reported parameter called the electrochemical index of glycosylation (EIG). Three rat groups were designed: saline group, cocaine group, and cocaine–alcohol group. Moreover, two periods of withdrawal were studied, after 2 days and 30 days. The alcohol–cocaine group after 2 days of withdrawal showed significantly lower EIG values (p < 0.1) than the rest of groups and also alcohol–cocaine group after 30 days of withdrawal, so the sensor was able to identify the alcohol consumption in rats and to monitor the recovery of glycosylation level after 30 days of withdrawal, even combined with cocaine. Furthermore, the effect of sex was also considered. Receiver operating characteristic (ROC) curves were developed for each sex and the corresponding cut-off values were determined. The sensor showed a clinical sensitivity of 70% for male and 75% for female, and a specificity of 67% for both sexes. This preclinical validation demonstrated the possibilities of this sensor for point of care testing of alcoholism, even in cocaine addicts, making it a potential tool for diagnosis and monitoring of alcohol consumption in detox treatments for humans.
Descripción
The registered version of this article, first published in “Chemosensors, 13(3), 97", is available online at the publisher's website: MDPI,https://doi.org/10.3390/chemosensors13030097
La versión registrada de este artículo, publicado por primera vez en “Chemosensors, 13(3), 97", está disponible en línea en el sitio web del editor: MDPI, https://doi.org/10.3390/chemosensors13030097
Categorías UNESCO
Palabras clave
alcoholism, point-of-care testing, carbohydrate-deficient transferrin, sensor, polydrug, diagnosis, rat plasma
Citación
Garrido-Matilla, L., María-Hormigos, R., Monago-Maraña, O., Marcos, A., Ambrosio, E., & Crevillen, A. G. (2025). Preclinical Validation of an Electrochemical Sensor for Alcohol Consumption Monitoring in a Polydrug Self-Administration Animal Model. Chemosensors, 13(3), 97. https://doi.org/10.3390/chemosensors13030097
Centro
Facultad de Ciencias
Departamento
Ciencias Analíticas
Grupo de investigación
Grupo de innovación
Programa de doctorado
Cátedra
Datos de investigación relacionados