Diagnostic accuracy of the Spanish version of the 4AT scale (4AT-ES) for delirium screening in older inpatients

dc.contributor.authorDelgado Parada, E.
dc.contributor.authorMorillo Cuadrado, Daniel Vicente
dc.contributor.authorSaiz Ruiz, J
dc.contributor.authorCebollada Gracia, A.
dc.contributor.authorAyuso Mateos, J.L.
dc.contributor.authorCruz Jentoft, A.J.
dc.contributor.authorMorillo Cuadrado, Daniel Vicente
dc.date.accessioned2024-12-05T11:35:04Z
dc.date.available2024-12-05T11:35:04Z
dc.date.issued2022-07
dc.descriptionLa versión registrada de este artículo, publicado por primera vez en The European Journal of Psychiatry, Volume 36, Issue 3, 2022, Pages 182-190, está disponible en línea en el sitio web del editor: https://doi.org/10.1016/j.ejpsy.2022.01.003 The copyrighted version of this article, first published in The European Journal of Psychiatry, Volume 36, Issue 3, 2022, Pages 182-190, is available online at the publisher's website: https://doi.org/10.1016/j.ejpsy.2022.01.003
dc.description.abstractAbstract Background and objectives The 4AT scale is a sensitive tool for screening delirium, which can be applied rapidly in clinical settings without any specific training. It has not been translated, adapted, and validated to assess Spanish older adults. The aims of the study are: to translate and adapt to Spanish culture the 4AT scale, to present evidence of the diagnostic accuracy of this version (4AT-ES) when applied in non-specialized hospital wards, and to assess the loss of diagnostic accuracy in presence of risk factors. Methods A prospective sample was independently assessed on the 4AT-ES and the reference standard. One hundred and twenty-one inpatients (70+ years) for whom a psychiatric assessment was requested were included. Out of them, 50 were diagnosed with delirium. Nurses without specific training applied the 4AT-ES, and experienced psychiatrists cast the reference standard diagnosis (DSM-V criteria). Results Patients with delirium were older and had more risk factors (more previous delirium episodes, a higher likelihood of prior dementia/cognitive impairment) than controls. The 4AT-ES had excellent validity, sensitivity (96%) , and specificity (83.1%). The area under the curve was 0.918; in the subsample with any of those risk factors, its value did not decrease. Conclusion The 4AT-ES version of the 4AT scale was developed. When applied by non-specifically trained, nursing staff it showed excellent validity, sensitivity, and specificity, even in a subsample with previous risk factors. All indices were comparable to the original version. We recommend its use for efficient delirium screening in hospitalized older patients with suspected delirium.en
dc.description.versionversión publicada
dc.identifier.citationE. Delgado-Parada, D. Morillo-Cuadrado, J Saiz-Ruiz, A. Cebollada-Gracia, J.L. Ayuso-Mateos, A.J. Cruz-Jentoft, Diagnostic accuracy of the Spanish version of the 4AT scale (4AT-ES) for delirium screening in older inpatients, The European Journal of Psychiatry, Volume 36, Issue 3, 2022, Pages 182-190, ISSN 0213-6163, https://doi.org/10.1016/j.ejpsy.2022.01.003.
dc.identifier.doihttps://doi.org/10.1016/j.ejpsy.2022.01.003
dc.identifier.issn0213-6163
dc.identifier.urihttps://hdl.handle.net/20.500.14468/24722
dc.journal.issue3
dc.journal.titleThe European Journal of Psychiatry
dc.journal.volume36
dc.language.isoen
dc.page.final190
dc.page.initial182
dc.publisherElsevier
dc.relation.centerFacultades y escuelas::Facultad de Psicología
dc.relation.departmentMetodología de las Ciencias del Comportamiento
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subject61 Psicología
dc.subject.keywordsDelirium screeningen
dc.subject.keywordsTranslationen
dc.subject.keywordsDiagnostic accuracyen
dc.subject.keywordsValidationen
dc.titleDiagnostic accuracy of the Spanish version of the 4AT scale (4AT-ES) for delirium screening in older inpatientsen
dc.typeartículoes
dc.typejournal articleen
dspace.entity.typePublication
relation.isAuthorOfPublicationeaf86785-e049-4e6e-a3cc-0409c8954333
relation.isAuthorOfPublication.latestForDiscoveryeaf86785-e049-4e6e-a3cc-0409c8954333
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
MorilloCuadrado_Daniel_Diagnostic_accuracy_of.pdf
Tamaño:
825.78 KB
Formato:
Adobe Portable Document Format
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
3.62 KB
Formato:
Item-specific license agreed to upon submission
Descripción: