Publicación: Evaluación de pérdidas de energía en motores eléctricos de inducción mediante termografía
Cargando...
Fecha
2024-10-22
Editor/a
Director/a
Tutor/a
Coordinador/a
Prologuista
Revisor/a
Ilustrador/a
Derechos de acceso
info:eu-repo/semantics/openAccess
Título de la revista
ISSN de la revista
Título del volumen
Editor
Universidad Nacional de Educación a Distancia (España), Universidad de Concepción - Chile. Departamento de Ingeniería Mecánica
Resumen
Controlar la eficiencia de los motores eléctricos de inducción (MI) en tiempo real es importante, ya que consumen cerca del 60% de la demanda energética a nivel industrial. Se llevaron a cabo corridas experimentales en un ambiente controlado bajo diferentes factores de carga (20, 40, 60, 80 y 100%) con una duración de 120 minutos cada una, bajo los mismos factores de carga se midió la eficiencia del MI con un método convencional (Torquímetro y mediciones de potencia eléctrica).En cada corrida luego de asegurar que el MI alcanzará un estado térmico estacionario se tomaron fotografías con una cámara termográfica (Imágenes IR) y se estimaron las pérdidas de energía por transferencia de calor en cada régimen de operación para obtener la eficiencia por el método IR, los resultados del métodos basado en IR se compararon con los obtenidos por el método convencional y se pudo demostrar mediante los resultados parciales una convergencia a la eficiencia medida en la zona de alta carga bajo diferentes consideraciones de transferencia de calor.
Monitoring the real-time efficiency of induction motors (IM) is crucial as they account for approximately 60% of industrial energy demand. Experimental runs were conducted in a controlled environment under different load conditions (20, 40, 60, 80, and 100%), each lasting 120 minutes. Under the same load conditions, IM efficiency was measured using a conventional method (torque meter and electrical power measurements). In each run, after ensuring that the IM reached a steady state thermal condition, infrared (IR) images were captured using a thermal camera. Energy losses due to heat transfer were estimated for each operating condition to determine efficiency using the IR method. The results from the IR-based method were compared with those obtained through the conventional method, and partial results demonstrated a convergence to the efficiency measured in the high-load region under various heat transfer considerations.
Monitoring the real-time efficiency of induction motors (IM) is crucial as they account for approximately 60% of industrial energy demand. Experimental runs were conducted in a controlled environment under different load conditions (20, 40, 60, 80, and 100%), each lasting 120 minutes. Under the same load conditions, IM efficiency was measured using a conventional method (torque meter and electrical power measurements). In each run, after ensuring that the IM reached a steady state thermal condition, infrared (IR) images were captured using a thermal camera. Energy losses due to heat transfer were estimated for each operating condition to determine efficiency using the IR method. The results from the IR-based method were compared with those obtained through the conventional method, and partial results demonstrated a convergence to the efficiency measured in the high-load region under various heat transfer considerations.
Descripción
Organizado y patrocinado por: Federación iberoamericana de Ingeniería Mecánica y 'Universidad de Concepción - Chile. Departamento de Mecánica', FeIbIm – FeIbEM
Categorías UNESCO
Palabras clave
Termografía, eficiencia, pérdidas de energía, Thermography, efficiency, energy losses