Publicación: Experimental evaluation of thermal comfort, ventilation performance indices and exposure to airborne contaminant in an airborne infection isolation room equipped with a displacement air distribution system
dc.contributor.author | Berlanga Cañete, Félix Antonio | |
dc.contributor.author | Ruiz de Adana, M. | |
dc.contributor.author | Olmedo, Inés | |
dc.contributor.author | Villafruela, José Manuel | |
dc.contributor.author | San José, J. F. | |
dc.contributor.author | Castro, F. | |
dc.contributor.orcid | https://orcid.org/0000-0003-1527-658X | |
dc.contributor.orcid | https://orcid.org/0000-0003-0491-4371 | |
dc.contributor.orcid | https://orcid.org/0000-0003-0491-4371 | |
dc.date.accessioned | 2024-12-11T14:05:12Z | |
dc.date.available | 2024-12-11T14:05:12Z | |
dc.date.issued | 2017-11-20 | |
dc.description | The registered version of this article, first published in Energy and Buildings, is available online at the publisher's website: Elsevier, https://doi.org/10.1016/j.enbuild.2017.09.100 | |
dc.description | La versión registrada de este artículo, publicado por primera vez en Energy and Buildings, está disponible en línea en el sitio web del editor: Elsevier, https://doi.org/10.1016/j.enbuild.2017.09.100 | |
dc.description.abstract | This study is focused on determining the convenience of the use of displacement ventilation strategy in airborne infection isolation rooms (AIIRs). Thermal comfort of the occupants of the chamber, ventilation and contaminant performance indices and the exposure of the health worker (HW) to the contaminants exhaled by the confined patient (P) are considered in a typical AIIR set up with two thermal breathing manikins and a radiant wall simulating an external wall. Three air renewal rates are tested to determine their influence in the studied variables. Results show that ventilation performance, contaminants and general comfort indices for both manikins perform well in the cases studied. Lockup phenomenon associated with displacement ventilation occurs above P but it has a low influence on contaminant exposure of HW because of the influence of the convective boundary layer of HW. The influence of the radiant wall could lock the air path near the exhaust grille. | es |
dc.description.version | versión final | |
dc.identifier.citation | Berlanga, F. A., de Adana, M. R., Olmedo, I., Villafruela, J. M., San José, J. F., & Castro, F. (2017). Experimental evaluation of thermal comfort, ventilation performance indices and exposure to airborne contaminant in an airborne infection isolation room equipped with a displacement air distribution system. Energy and Buildings, 158, 209-221. https://doi.org/10.1016/j.enbuild.2017.09.100 | |
dc.identifier.doi | https://doi.org/10.1016/j.enbuild.2017.09.100 | |
dc.identifier.issn | 0378-7788 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14468/24828 | |
dc.journal.title | Energy and Buildings | |
dc.journal.volume | 158 | |
dc.language.iso | en | |
dc.page.final | 221 | |
dc.page.initial | 209 | |
dc.publisher | Elsevier | |
dc.relation.center | Facultades y escuelas::E.T.S. de Ingenieros Industriales | |
dc.relation.department | Mecánica | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | |
dc.subject | 33 Ciencias Tecnológicas::3313 Tecnología e ingeniería mecánicas | |
dc.subject.keywords | air distribution | en |
dc.subject.keywords | displacement ventilation | en |
dc.subject.keywords | isolation room | en |
dc.subject.keywords | personal exposure | en |
dc.subject.keywords | human breathing | en |
dc.subject.keywords | ventilation effectiveness | en |
dc.subject.keywords | thermal plume | en |
dc.subject.keywords | thermal comfort | en |
dc.title | Experimental evaluation of thermal comfort, ventilation performance indices and exposure to airborne contaminant in an airborne infection isolation room equipped with a displacement air distribution system | en |
dc.type | artículo | es |
dc.type | journal article | en |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | d3d13d8a-e397-42e6-8b75-d90dc1020555 | |
relation.isAuthorOfPublication.latestForDiscovery | d3d13d8a-e397-42e6-8b75-d90dc1020555 |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Experimental evaluation of thermal comfort.pdf
- Tamaño:
- 981.98 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 3.62 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: