Abstract
Se desarrolló un simulador gástrico el cual permite llevar a cabo el análisis de desintegración química de alimentos y productos nutricionales, así como el análisis de disolución de fármacos en condiciones muy similares a las encontradas en el proceso gástrico humano en la región distal. El simulador gástrico distal in vitro se fabricó mediante manufactura aditiva. Consta de membranas blandas que permite simular las paredes gástricas que permiten generar el movimiento de manera cercana al comportamiento fisiológico. Con el fin de evaluar la capacidad de disolución de fármacos en el simulador gástrico se empleó prednisona, el cual es un estándar de verificación en pruebas de disolución aprobado por la farmacopea de los Estados Unidos (USP). Los resultados se compararon con uno de los dispositivos aprobados por la USP. Los resultados obtenidos permitieron llevar a cabo el análisis de disolución en condiciones mucho más reales y cercanas al proceso humano en comparación con el dispositivo propuesto por la USP.
A gastric simulator was developed which allows carrying out the analysis of chemical disintegration of foods and nutritional products, as well as the analysis of drug dissolution under conditions very similar to those found in the human gastric process in the distal region. The in vitro distal gastric simulator was fabricated by means of additive manufacture. It consists of soft membranes that simulate the gastric walls that allow movement to be generated in a way that is close to the physiological behavior. In order to evaluate the dissolution capacity of drugs in the gastric simulator, prednisone was used, which is a verification standard in dissolution tests approved by the United States Pharmacopeia (USP). The results were compared to one of the USP approved devices. The results obtained allowed the dissolution analysis to be carried out in conditions that were much more realistic and closer to the human process compared to the device proposed by USP.
A gastric simulator was developed which allows carrying out the analysis of chemical disintegration of foods and nutritional products, as well as the analysis of drug dissolution under conditions very similar to those found in the human gastric process in the distal region. The in vitro distal gastric simulator was fabricated by means of additive manufacture. It consists of soft membranes that simulate the gastric walls that allow movement to be generated in a way that is close to the physiological behavior. In order to evaluate the dissolution capacity of drugs in the gastric simulator, prednisone was used, which is a verification standard in dissolution tests approved by the United States Pharmacopeia (USP). The results were compared to one of the USP approved devices. The results obtained allowed the dissolution analysis to be carried out in conditions that were much more realistic and closer to the human process compared to the device proposed by USP.
Description
Organizado y patrocinado por: Federación iberoamericana de Ingeniería Mecánica y 'Universidad de Concepción - Chile. Departamento de Mecánica', FeIbIm – FeIbEM
UNESCO Categories
Keywords
peristalsis, simulador gástrico, disolución, farmacopea EU, peristalsis, gastric simulator, dissolution, US pharmacopeia
Citation
-
Center
E.T.S. de Ingenieros Industriales
Department
Mecánica