Publicación: Análisis exergético del R290 como sustituto del R410A en un acondicionador de aire variable operando con diferentes cargas de refrigerante
Cargando...
Archivos
Fecha
2022
Editor/a
Director/a
Tutor/a
Coordinador/a
Prologuista
Revisor/a
Ilustrador/a
Derechos de acceso
info:eu-repo/semantics/openAccess
Título de la revista
ISSN de la revista
Título del volumen
Editor
['Universidad Nacional de Educación a Distancia (España)', 'Universidad Politécnica de Madrid. Departamento de Ingeniería Mecánica']
Resumen
Este estudio evalúa experimentalmente el R290 como sustituto del R410A en un equipo acondicionador de aire variable operando con diferentes cargas de refrigerante a partir de un análisis de exergía. El trabajo experimental se realizó siguiendo el método del calorímetro balanceado según la norma ISO-5151, en un equipo acondicionador de aire tipo mini-split de 18000 Btu/h. Durante los ensayos se cuantifico la capacidad de enfriamiento, el consumo de energía, las presiones y temperaturas del equipo, operando con 7 cargas de R410A y 5 cargas de R290. Entre los resultados principales se encontró que el compresor presenta mayor exergía destruida por la carga de refrigerante, debido principalmente al incremento del calor en el equipo. Por otro lado, al comparar los refrigerantes se observó menor destrucción de exergía y mayor eficiencia exergética operando con R290. Sin embargo, la capacidad de enfriamiento se disminuye significativamente en el R290 en comparación con R410A.
This study experimentally evaluates R290 as a substitute for R410A in a variable air conditioner operating with different refrigerant charges based on an exergy analysis. The experimental work was carried out following the balanced calorimeter method according to ISO-5151, in an 18000 Btu/h mini-split air conditioner. During the tests, the cooling capacity, energy consumption, pressures and temperatures of the equipment were quantified, operating with 7 charges of R410A and 5 charges of R290. Among the main results it was found that the compressor has more exergy destroyed by the refrigerant charge, due to the increase of heat in the equipment. On the other hand, when comparing refrigerants, less exergy destruction and higher exergy efficiency was observed operating with R290. However, the cooling capacity is significantly reduced in R290 compared to R410A.
This study experimentally evaluates R290 as a substitute for R410A in a variable air conditioner operating with different refrigerant charges based on an exergy analysis. The experimental work was carried out following the balanced calorimeter method according to ISO-5151, in an 18000 Btu/h mini-split air conditioner. During the tests, the cooling capacity, energy consumption, pressures and temperatures of the equipment were quantified, operating with 7 charges of R410A and 5 charges of R290. Among the main results it was found that the compressor has more exergy destroyed by the refrigerant charge, due to the increase of heat in the equipment. On the other hand, when comparing refrigerants, less exergy destruction and higher exergy efficiency was observed operating with R290. However, the cooling capacity is significantly reduced in R290 compared to R410A.
Descripción
Categorías UNESCO
Palabras clave
Acondicionador de aire, exergía, R290, R410A