Desarrollo de un modelo numérico aplicando fundamentos biomecánicos para sanar fractura de coronoides del codo utilizando fijación con tres tornillos de titanio

dc.contributor.authorTrejo Enríquez,Alfonso
dc.contributor.authorIslas Jiménez, Dante Abel
dc.contributor.authorUrriolagoitia Sosa, Guillermo
dc.contributor.authorRomero Ángeles, Beatriz
dc.contributor.authorMaya Anaya, Daniel
dc.contributor.authorHernández Patiño, Omar Isaac
dc.contributor.authorCruz López, Salvador
dc.contributor.authorSánchez Cervantes, Arturo
dc.contributor.authorCorrea Corona, Martin Ivan
dc.contributor.editorUniversidad Nacional de Educación a Distancia (España)
dc.contributor.editorUniversidad Politécnica de Madrid. Departamento de Ingeniería Mecánica
dc.date.accessioned2024-07-05T10:15:49Z
dc.date.available2024-07-05T10:15:49Z
dc.date.issued2022-11-22
dc.description.abstractLa fractura de codo es una de las principales limitaciones que proporciona la estabilidad de la articulación humeral. Este tipo de fractura puede ser un hallazgo aislado después de la luxación del codo o en parte de una terrible triada del codo. La luxación de codo es una lesión común, que representa el 10% de los traumatismos sobre dicha articulación. Normalmente suelen producirse por accidentes deportivos o automovilísticos En este trabajo se presenta el desarrollo de un nuevo modelo numérico del antebrazo (radio y cúbito) para ser utilizado para evaluar el proceso de fijación de tornillos esponjosos de titanio. El diseño de los tornillos se realizó de acuerdo a las normas establecidas. Así como, la fijación de los tornillos se desarrolló de acuerdo al caso clínico de un joven masculino que había sufrido previamente fractura en este sistema biológico. Cabe señalar que la posición de los tornillos es idéntica al caso clínico mencionado. También se realizaron orificios al biomodelo del codo, estos sirven para la fijación de los tornillos, otorgando confiabilidad en los análisis realizados, ya que es un modelo idéntico a la vida real. Los resultados obtenidos en esta investigación son confiables y con funcionalidad para análisis futuros.es
dc.description.abstractThe elbow fracture is one of the main limitations that provides the stability of the humeral joint. This fracture type can be an isolated finding after elbow dislocation or part of a terrible elbow triad. Elbow dislocation is a common injury, accounting for 10% of injuries to that joint. Usually caused by sports or car accidents. The most frequent complications are stiffness and instability. This paper presents the development of a new numerical model of the forearm (radius and ulna) to evaluate the fixation process of cancellous Titanium screws. The design of the screws was performed according to the established standards. Additionally, the fixation of the screws was developed according to the clinical case of a young male who had previously suffered a fracture in this biological system. It should be note that the position of the screws is identical to the aforementioned clinical case. Holes to fix the screws were produced in the biomodel of the elbow, providing reliability in the evaluation (since it is a model identical to real life). The results obtained in this research are reliable and functional for future analyses.en
dc.description.versionversión publicada
dc.identifier.citationTrejo Enríquez,Alfonso, Islas Jiménez, Dante Abel, Urriolagoitia Sosa, Guillermo, Romero Ángeles, Beatriz, Maya Anaya, Daniel, Hernández Patiño, Omar Isaac, Cruz López, Salvador, Sánchez Cervantes, Arturo y Correa Corona, Martin Ivan(2022) .Desarrollo de un modelo numérico aplicando fundamentos biomecánicos para sanar fractura de coronoides del codo utilizando fijación con tres tornillos de titanio. XV Congreso Iberoamericano de Ingeniería Mecánica.En: Universidad Politécnica de Madrid. (2022-11-22)
dc.identifier.doihttps://doi.org/10.5944/bicim2022.113
dc.identifier.urihttps://hdl.handle.net/20.500.14468/22841
dc.language.isoen
dc.relation.centerE.T.S. de Ingenieros Industriales
dc.relation.congressXV Congreso Iberoamericano de Ingeniería Mecánicaes
dc.relation.departmentMecánica
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subject33 Ciencias Tecnológicas::3313 Tecnología e ingeniería mecánicas
dc.subject.keywordsantebrazoes
dc.subject.keywordssimulación numéricaes
dc.subject.keywordsfracturaes
dc.subject.keywordsmétodo de Elemento Finitoes
dc.subject.keywordsforearmen
dc.subject.keywordsnumerical simulation,en
dc.subject.keywordsfractureen
dc.subject.keywordsfinite Element Methoden
dc.titleDesarrollo de un modelo numérico aplicando fundamentos biomecánicos para sanar fractura de coronoides del codo utilizando fijación con tres tornillos de titanioes
dc.titleDevelopment of a numerical model applying biomechanical foundations to heal coronoid fracture of the elbow using fixation with three titanium screwsen
dc.typeactas de congresoes
dc.typeconference proceedingsen
dspace.entity.typePublication
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Abs_155_195249-Desarrollo de un modelo numerico.pdf
Tamaño:
1.02 MB
Formato:
Adobe Portable Document Format
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
3.62 KB
Formato:
Item-specific license agreed to upon submission
Descripción: