Publicación:
Modelo geométrico predictor de dosis en órganos de riesgo en tratamientos de mama con radioterapia externa de haces tangenciales

dc.contributor.authorDíez Chamarro, Javier
dc.contributor.directorBarranco López, Alejandro
dc.contributor.directorSanta Marta Pastrana, Cristina María
dc.date.accessioned2024-05-20T12:21:48Z
dc.date.available2024-05-20T12:21:48Z
dc.date.issued2022-03-11
dc.description.abstractEn este trabajo se presenta un modelo basado en la anatomía del paciente para predecir el porcentaje de volumen del pulmón ipsilateral y/o corazón que recibe al menos cierta dosis en tratamientos de mama con campos tangenciales estáticos de radioterapia externa. El modelo se basa en una correlación entre el porcentaje de órgano sano que es irradiado de forma directa por el haz tangencial y la variable a predecir citada anteriormente: porcentaje de órgano sano que recibe al menos cierta dosis. Una de las claves del modelo es calcular la primera variable, porcentaje de órgano sano que es irradiado de forma directa por el haz tangencial, a partir del archivo de estructuras DICOM de cada paciente. La predicción se realiza a partir de esta variable, computada por un programa que se ha desarrollado a tal efecto, y de la ecuación de la recta de correlación de la dosis a predecir. Para obtener la pendiente y la ordenada en el origen es necesario calibrar el modelo a partir de tratamientos ya planificados, cuya distribución de dosis absorbida en los órganos de interés es conocida. Se han calibrado (obtenido rectas de correlación) dos modelos independientes por lateralidad de la enfermedad: pulmón derecho en irradiación exclusiva de mama derecha y pulmón izquierdo y corazón en izquierda. Ambos modelos muestran buena correlación en el rango de dosis comprendido entre el 20 y el 90% de la dosis de prescrita en la mama afecta y correlación excepcionalmente buena entre el 35 y el 85%.es
dc.description.abstractIn this work, a patient anatomy based model to predict the percentaje of ipsilateral lung and/or heart which absorbs at least certain dose in breast tangential external radiotherapy is presented. The model is based on a correlation between the percentage of irradiated healthy lung/cardiac tissue under direct tangential beam and the last mentioned variable: percentage of healthy tissue that absorbs at least certain dose. A model key point is to determinate the first variable, percentage of healthy tissue under direct tangential beam, using patient DICOM structure file. Prediction is made from this value, computed by a program that has been developed for that purpose, and the desired dose correlation line equation. In order to obtain line slope and line vertical axis interception value, a calibration of the model from already planified treatments, whose dose spatial distribution is known, has to be made. Two independend models have been calibrated by laterality: right lung on exclusive whole right breast irradiation and left lung and heart on left breast. Both models show good correlation for doses ranging from 20 to 90 % of prescribed dose and exceptional correlation ranging from 35 to 85 %.en
dc.description.versionversión final
dc.identifier.urihttps://hdl.handle.net/20.500.14468/14024
dc.language.isoes
dc.publisherUniversidad Nacional de Educación a Distancia (España). Facultad de Ciencias. Departamento de Física Matemática y de Fluidos
dc.relation.centerFacultad de Ciencias
dc.relation.degreeMáster universitario en Física Médica
dc.relation.departmentFísica Matemática y de Fluídos
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.titleModelo geométrico predictor de dosis en órganos de riesgo en tratamientos de mama con radioterapia externa de haces tangencialeses
dc.typetesis de maestríaes
dc.typemaster thesisen
dspace.entity.typePublication
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
DiezChamarro_Javier_TFM_TCI.pdf
Tamaño:
6.63 MB
Formato:
Adobe Portable Document Format