Persona: García Ybarra, Pedro Luis
Cargando...
Dirección de correo electrónico
ORCID
0000-0001-6173-6087
Fecha de nacimiento
Proyectos de investigación
Unidades organizativas
Puesto de trabajo
Apellidos
García Ybarra
Nombre de pila
Pedro Luis
Nombre
6 resultados
Resultados de la búsqueda
Mostrando 1 - 6 de 6
Publicación Feasibility of ultra-low Pt loading electrodes for high temperature proton exchange membrane fuel cells based in phosphoric acid-doped membrane(ELSEVIER, 2019) Martín Fernández, Santiago; Jensen, Jens Oluf; Li, Qingfeng; García Ybarra, Pedro Luis; Castillo Gimeno, José Luis; https://orcid.org/0000-0002-2427-7763; https://orcid.org/0000-0002-5460-055XFactors as the Pt/C ratio of the catalyst, the binder content of the electrode and the catalyst deposition method were studied within the scope of ultra-low Pt loading electrodes for high temperature proton exchange membrane fuel cells (HT-PEMFCs). The Pt/C ratio of the catalyst allowed to tune the thickness of the catalytic layer and so to minimize the detrimental effect of the phosphoric acid flooding. A membrane electrode assembly (MEA) with 0.05 mgPtcm−2 at anode and 0.1 mgPtcm−2 at cathode (0.150 mgPtcm−2 in total) attained a peak power density of 346 mW cm−2. It was proven that including a binder in the catalytic layer of ultra-low Pt loading electrodes lowers its performance. Electrospraying-based MEAs with ultra-low Pt loaded electrodes (0.1 mgPtcm−2) rendered the best (peak power density of 400 mW cm−2) compared to conventional methods (spraying or ultrasonic spraying) but with the penalty of a low catalyst deposition rate.Publicación Evolution of CO2 concentration in indoor-room environments with different ventilation modes(ELSEVIER, 2026-04-26) García Corral, Álvaro; Düsing, Sebastian; Alas, Honey Dawn C.; Hof, Henrik; Ziegler, Volker; García Ybarra, Pedro Luis; Castillo Gimeno, José Luis; Ministerio de Ciencia, Investigación y Universidades (España)Measuring and controlling ventilation rates (VRs) in buildings is important to meet requirements on indoor air quality and energy efficiency. Measurements of CO2 steady-state concentrations can be used for this purpose, but the accuracy of this method is limited, and reaching saturation under realistic constant occupancy levels can be challenging and time-consuming. Here, the general solution of the CO2-balance equation is employed to model and fit transient CO2 concentrations measured in large indoor rooms at high occupancies. The evolution of CO2 concentration was recorded for real-use conditions over several hours or days in a conference room, an auditorium, and a large multipurpose room during a multitudinous conference. Each space has one or several modes of ventilation, namely a ventilated air-conditioning system, natural ventilation, and/or infiltration. Total and mode-specific VRs were derived, evaluated, and compared with current standards. By assuming mean CO2 generation rates per person, room occupancies during different events in each room could be estimated. The same procedure was repeated for a regular coworking office, demonstrating the applicability of this method to smaller rooms and lower occupancies. Additionally, a non-dimensionalization of the balance equation is employed to assess the accuracy of steady-state CO2 concentrations predicted by transient-state fits. The obtained non-dimensional relations provide a basis for designing ventilation systems in new buildings to avoid excessive CO2 levels at maximum occupancy and ensure sufficient ventilation. These results emphasize the importance of adequate ventilation to maintain acceptable indoor air quality for variable or even low occupancy.Publicación Noticias del Decanato : El nuevo edificio de la Facultad de Ciencias en el futuro Campus Científico-Tecnológico de Las Rozas(Universidad Nacional de Educación a Distancia (España). Facultad de Ciencias, 2011-01-01) García Ybarra, Pedro LuisPublicación Performance constraints of high temperature polymer electrolyte membrane fuel cells by varying the Pt/C ratio of the catalyst(ELSEVIER, 2024) Martín Fernández, Santiago; García Ybarra, Pedro Luis; Castillo Gimeno, José LuisElectrodes prepared from catalysts with Pt weight percentages on the carbon support (Pt/C nanoparticles) ranging from 10 up to 60 wt% are used as cathodes of membrane electrode assemblies (MEAs) and tested in high temperature polymer electrolyte membrane fuel cells (HT-PEMFCs). For each Pt/C percentage in the catalyst, the cathode Pt-loading (which become proportional to the thickness of the electrode formed by the catalyst nanoparticles) is stepwise scanned from low to high loadings. Results show that when the Pt load increases, the MEA performance (measured by its power density at 0.6 V) rises initially (due to the increase in the number of active sites in the cathode) up to a maximum value limited by the mass transport of oxygen, associated to an optimum Pt-loading (different for each Pt/C ratio). Noteworthy, the peak performance is significantly different depending on the catalyst used (60 > 40 >> 20 > 10 wt% Pt/C), a fact that restricts the catalyst choice according to the performance required by the application. Furthermore, higher amounts of Pt in the cathode lead to a large catalyst waste as the FC performance even decreases as the cathode thickness increases.Publicación Congresos, seminarios, reuniones científicas y cursos de verano: Jornada Hidrógeno y Pilas de Combustible. Sistemas energéticos duales y sostenibles: desafíos y oportunidades(Universidad Nacional de Educación a Distancia (España). Facultad de Ciencias, 2018-01-01) García Ybarra, Pedro LuisPublicación Prediction of an optimal cathode catalyst loading in PEM fuel cells from a macro-homogeneous porous-electrode model perspective(Elsevier, 2026-07-22) García Corral, Álvaro; Martín Fernández, Santiago; González Rodríguez, Leandro; Castillo Gimeno, José Luis; García Ybarra, Pedro Luis; Agencia Estatal de Investigación (España); Ministerio de Industria, Comercio y Turismo (España)In general, the performance of polymer-electrolyte membrane fuel cells (PEMFCs) improves when the Pt-loading of the cathode catalyst layer (CCL) is augmented. However, if augmenting the Pt-loading carries along an increase of CCL thickness, enhanced limitations in electrical and reactant transport phenomena cause a counterproductive increase in the cathode activation overpotential. In fact, experiments show the existence of an optimal Pt-loading at which performance peaks, decreasing in thicker CCLs. Here, the macro-homogeneous porous model is revisited and developed to account for this behavior. By expressing the overpotential in terms of the oxygen concentration across the CCL, the system of governing equations (under Tafel's approximation) could be reduced to one-single dimensionless equation, substantially diminishing its complexity. A novel rescaling of the problem variables is introduced to further simplify this equation, with a straightforward solution in three limit regimes. The general case was solved numerically, determining the concentration and overpotential profiles across the CCL, and the polarization curve. Despite its mathematical simplicity, this framework can be used to reproduce fundamental behaviors, here being successfully employed to describe and comprehend the origin of the emergence of the local maximum of PEMFC performance under varying Pt-loading and CCL thickness.