Mostrando 1 - 7 de 7
  • Publicación
    Improved Operation and Stability of a Wind-Hydro Microgrid by Means of a Li-Ion Battery Energy Storage
    (MDPI, 2022-12-06) Sebastián Fernández, Rafael
    This article presents an isolated microgrid which combines two renewable power generators: a Hydraulic-Turbine-Generator (HTG) and a Wind-Turbine-Generator (WTG) with a Li-ion battery-energy-storage (BES). Depending on the generator(s) which supply active power, the microgrid can operate in three modes: Hydro-Only (HO), Wind-Hydro (WH) and Wind-Only (WO). In WH mode, the HTG supplies the difference between the power demanded by the consumers and the power supplied by the WTG. This net demanded power can be negative when the WTG power is greater than the load and this situation can lead to a microgrid collapse. This article shows by means of simulations how the BES is controlled to consume the WTG power excess guaranteeing the microgrid stability. Additionally, when the negative net demanded load is persistent the microgrid must transition from WH mode to WO mode, where only the WTG supplies active power, and this WH-WO transition is also simulated. In the simulations in WO mode, the BES is controlled to regulate the microgrid frequency. The needed controls to command the BES in WH and WO modes and in the WH-WO transition are also explained. The simulations show the effectiveness of using the BES since the microgrid stability and reliability is improved.
  • Publicación
    Reliability of autonomous solar-wind microgrids with battery energy storage system applied in the residential sector
    (Elsevier, 2023-06-08) Zarate Pérez, Eliseo Juan; Santos-Mejia, Cesar; Sebastián Fernández, Rafael
    Residential electricity generation can benefit from the successful deployment of photovoltaic (PV) and wind renewable energy sources. However, their intermittent nature poses a significant limitation. To address this, a hybrid system can be employed to enhance system reliability and efficiency. Reliability analysis plays a crucial role in evaluating the energy production capacity to meet the demand. This study aims to assess the reliability of a hybrid PV/wind microgrid through simulation. Data from a residence were collected every 10 s, and average values were computed on an hourly basis and exported for computer processing. Solar irradiation, wind speed, and temperature data were also utilized. The modeling process involved defining the PV panel, wind turbines, battery energy storage system (BESS), management strategy, and energy autonomy. The results indicate that when PV and wind systems operate independently, they are unable to consistently reduce the residential energy deficit. However, the PV/Wind/BESS configuration significantly improves system operation and proves sufficient to meet the required load in most hours. Through this configuration, only 42.5% of the total PV/wind energy utilized by the residents needs to be dispatched through the BESS. Moreover, the BESS capacity is reduced by 50% when the systems are used separately. The public grid only supplies power when the BESS is insufficient to cover the load. Therefore, the optimal sizing of the BESS plays a critical role in system viability, reducing initial installation costs, regulating microgrid parameters, and contributing to the reduction of the energy deficit. Hence, investigating the fundamental design parameters of the microgrid and BESS is essential for identifying the optimal capacity of the system and ensuring model reliability. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under theCCBYlicense (http://creativecommons.org/licenses/by/4.0/).
  • Publicación
    Review on Dynamic Simulation of Wind Diesel Isolated Microgrids
    (MDPI, 2021-03-24) Sebastián Fernández, Rafael
    Wind diesel isolated microgrids (WDIMs) combine wind turbine generators (WTGs) with diesel generators (DGs) to supply electricity to remote consumers. WDIMs are low-inertia isolated power systems where large system frequency and voltage variations occur. WDIM dynamic modeling allows short-term simulations to be performed and detailed electrical variable transients to be obtained so that the WDIM power quality and stability can be tested. This paper presents a literature review about WDIM dynamic simulation. The review classifies articles according to factors such as the different WDIM operation modes (diesel only, wind–diesel and wind only) simulated, the types of WTGs used in the WDIM (constant- and variable-speed types), or the use of different short-term energy storage technologies (batteries, ultracapacitors, flywheels) to improve the WDIM power quality, stability and reliability. Papers about the dynamic simulation of related isolated microgrids are also reviewed. Finally, as an example of WDIM dynamic simulation, a WDIM with one WTG, one DG, load and a discrete dump load (DL) is modeled and simulated. The WDIM response to variations of wind speed and load consumption is shown by graphs of the main electrical variables. The simulations show how the DL is used to improve the WDIM stability and reliability.
  • Publicación
    Frequency control in an isolated wind-diesel hybrid system with energy storage and an irrigation water supply system
    (Wiley/Institution of Engineering and Technology (IET), 2024-04-04) Monroy Morales, Jose Luis; Pena Alzola, Rafael; Sebastián Fernández, Rafael; Campos Gaona, David; Castellano Quesada, Jeronimo; Guardado, Jose L.
    Wind-Diesel Hybrid Systems (WDHSs) integrate wind turbines into diesel power systems, reducing costs and emissions in isolated grids. Due to the no-load consumption of the Diesel Generators (DGs), fuel savings are only possible when the DGs are shut down. This requires a proper implementation of the frequency control to avoid perturbations because of the wind speed variations. During wind-only (WO) operation, the Synchronous Machine (SM) generates the isolated grid voltage and the frequency controller varies the energy stored/supplied by an Energy Storage System and consumed by the controllable loads to balance the power. In this paper, a Battery-based Energy Storage System (BESS) uses Li-Ion batteries with a Dual Active Bridge (DAB) and a grid-tie inverter connected to the isolated network. The controllable load is an Irrigation Water Supply System (IWSS), consisting of a pump supplying water to a reservoir tank. The pump is driven by a variable speed drive that uses a Permanent Magnet Synchronous Motor (PMSM). The coordinated control of BESS and IWSS gives full priority to the BESS for harnessing the wind potential whereas the IWSS consumes the excess of wind power. The full Wind Diesel Power System (WDPS) is modelled and simulated to validate the proposed system for different case scenarios.Wind-Diesel Hybrid Systems (WDHSs) integrate wind turbines into diesel power systems. This requires a proper implementation of the frequency control to avoid perturbations because of the wind speed variations. In this paper, a Battery-based Energy Storage System (BESS) uses Li-Ion batteries with a Dual Active Bridge (DAB) and a grid-tie inverter connected to the isolated network. The controllable load is an Irrigation Water Supply System (IWSS), consisting of a pump supplying water to a reservoir tank driven by a variable speed drive. The coordinated control of BESS and IWSS gives full priority to the BESS for harnessing the wind potential whereas the IWSS consumes the excess of wind power. The full WDPS is modelled and simulated to validate the proposed system for different case scenarios. image
  • Publicación
    Assessment and Optimization of Residential Microgrid Reliability Using Genetic and Ant Colony Algorithms
    (MDPI, 2025-03-04) Zarate Pérez, Eliseo Juan; Sebastián Fernández, Rafael
    The variability of renewable energy sources, storage limitations, and fluctuations in residential demand affect the reliability of sustainable energy systems, resulting in energy deficits and the risk of service interruptions. Given this situation, the objective of this study is to diagnose and optimize the reliability of a residential microgrid based on photovoltaic and wind power generation and battery energy storage systems (BESSs). To this end, genetic algorithms (GAs) and ant colony optimization (ACO) are used to evaluate the performance of the system using metrics such as loss of load probability (LOLP), loss of supply probability (LPSP), and availability. The test system consists of a 3.25 kW photovoltaic (PV) system, a 1 kW wind turbine, and a 3 kWh battery. The evaluation is performed using Python-based simulations with real consumption, solar irradiation, and wind speed data to assess reliability under different optimization strategies. The initial diagnosis shows limitations in the reliability of the system with an availability of 77% and high values of LOLP (22.7%) and LPSP (26.6%). Optimization using metaheuristic algorithms significantly improves these indicators, reducing LOLP to 11% and LPSP to 16.4%, and increasing availability to 89%. Furthermore, optimization achieves a better balance between generation and consumption, especially in periods of low demand, and the ACO manages to distribute wind and photovoltaic generation more efficiently. In conclusion, the use of metaheuristics is an effective strategy for improving the reliability and efficiency of autonomous microgrids, optimizing the energy balance and operating costs.
  • Publicación
    Autonomy evaluation model for a photovoltaic residential microgrid with a battery storage system
    (Elsevier, 2022-08-01) Zarate Pérez, Eliseo Juan; Sebastián Fernández, Rafael
    The dependence on fossil resources remains high, accounting for 80% of the total primary energy production worldwide. In addition, the COVID-19 pandemic has devastated several industries and electric power is no exception. Therefore, renewable energy sources have become an important aspect of the energy sector, contributing to solutions to environmental problems and the development of a sustainable future. Therefore, this study proposes a model to evaluate the energy autonomy of a photovoltaic microgrid (EA(PV,MG)) using a battery energy storage system (BESS). To carry out the analysis, the energy consumption history of a residence and the solar irradiation data of the location were used. Thus, this study includes the evaluation of the energy compensation of a photovoltaic microgrid that directly injects energy into the residence, and the surplus is stored in a BESS for later use. The results show the relevance of EA(PV, MG) modeling for optimal system sizing. The model determines the autonomy of the microgrid without many power variations in the PV system for January, April, and October, corresponding to the summer, autumn, and spring seasons, respectively. However, in July (winter), the photovoltaic MG must increase the installation power considerably and the storage capacity of the BESS. Therefore, an optimal decision evaluating the EA(PV,MG) will allow broadening an overview to opt for a PV microgrid that injects the highest amount of energy based on the actual residential load profile and the optimal capacity of the BESS. Consequently, the analysis of the EA of a microgrid based on solar irradiation and actual load data is essential for developing an optimal and stable operation of the residential energy system. (C) 2022 The Author(s). Published by Elsevier Ltd.
  • Publicación
    Frequency Response Enhancement of an Islanded Hydro Turbine-Based Microgrid Using Battery Storage and Adaptive Predictive Control
    (Institute of Electrical and Electronics Engineers (IEEE), 2026-06-04) Nevado Reviriego, Antonio; Sebastián Fernández, Rafael
    Hydraulic turbine generators (HTG) inherently exhibit slow dynamic responses; therefore, when operating as the sole power source in an islanded microgrid (MG), they may be unable to comply with the frequency limits imposed by existing grid codes for islanded MG under all operating conditions. By means of simulations, this article shows how an islanded MG supplied exclusively by an HTG and equipped with a classical governor results in frequency excursions beyond the 46/53 Hz limits defined in applicable grid codes for islanded MG when 0.17 per unit positive/negative load steps are applied. Settling times in this case are as long as 23/22 s. This work demonstrates that, by adding a small capacity battery energy storage (BES) of 11.9 kWh to the islanded grid along with an adaptive predictive controller (APC), which controls the sum of the powers provided by the HTG and the BES, the dynamic behavior of the islanded MG is greatly improved. Through simulations of the HTG+BES+APC grid, it is shown that the minimum/maximum frequency deviations in the upgraded MG are smaller (48.73/51.245 Hz) and the settling times are greatly reduced to 2.8/3 s for the same load steps, respectively. The simulations show that the BES+APC combination dramatically improves the islanded MG dynamics.