Fecha
2024-04-04
Derechos de acceso
info:eu-repo/semantics/openAccess
Título de la revista
ISSN de la revista
Título del volumen
Editorial
Wiley/Institution of Engineering and Technology (IET)
Resumen
Wind-Diesel Hybrid Systems (WDHSs) integrate wind turbines into diesel power systems, reducing costs and emissions in isolated grids. Due to the no-load consumption of the Diesel Generators (DGs), fuel savings are only possible when the DGs are shut down. This requires a proper implementation of the frequency control to avoid perturbations because of the wind speed variations. During wind-only (WO) operation, the Synchronous Machine (SM) generates the isolated grid voltage and the frequency controller varies the energy stored/supplied by an Energy Storage System and consumed by the controllable loads to balance the power. In this paper, a Battery-based Energy Storage System (BESS) uses Li-Ion batteries with a Dual Active Bridge (DAB) and a grid-tie inverter connected to the isolated network. The controllable load is an Irrigation Water Supply System (IWSS), consisting of a pump supplying water to a reservoir tank. The pump is driven by a variable speed drive that uses a Permanent Magnet Synchronous Motor (PMSM). The coordinated control of BESS and IWSS gives full priority to the BESS for harnessing the wind potential whereas the IWSS consumes the excess of wind power. The full Wind Diesel Power System (WDPS) is modelled and simulated to validate the proposed system for different case scenarios.Wind-Diesel Hybrid Systems (WDHSs) integrate wind turbines into diesel power systems. This requires a proper implementation of the frequency control to avoid perturbations because of the wind speed variations. In this paper, a Battery-based Energy Storage System (BESS) uses Li-Ion batteries with a Dual Active Bridge (DAB) and a grid-tie inverter connected to the isolated network. The controllable load is an Irrigation Water Supply System (IWSS), consisting of a pump supplying water to a reservoir tank driven by a variable speed drive. The coordinated control of BESS and IWSS gives full priority to the BESS for harnessing the wind potential whereas the IWSS consumes the excess of wind power. The full WDPS is modelled and simulated to validate the proposed system for different case scenarios. image
Descripción
The registered version of this article, first published in “IET Renewable Power Generation 18, 1040–1054 (2024)", is available online at the publisher's website: https://doi.org/10.1049/rpg2.12950
La versión registrada de este artículo, publicado por primera vez en “IET Renewable Power Generation 18, 1040–1054 (2024)", está disponible en línea en el sitio web del editor: https://doi.org/10.1049/rpg2.12950
La versión registrada de este artículo, publicado por primera vez en “IET Renewable Power Generation 18, 1040–1054 (2024)", está disponible en línea en el sitio web del editor: https://doi.org/10.1049/rpg2.12950
Categorías UNESCO
Palabras clave
diesel-electric power stations, energy storage, frequency control, hybrid power systems, power control, water pumps, wind power plants
Citación
Monroy-Morales, J.L., Peña-Alzola, R., Sebastián-Fernández, R., Campos-Gaona, D., Castellano, J.Q., Guardado, J.L.: Frequency control in an isolated wind-diesel hybrid system with energy storage and an irrigation water supply system. IET Renew. Power Gener. 18, 1040–1054 (2024). https://doi.org/10.1049/rpg2.12950
Centro
E.T.S. de Ingenieros Industriales
Departamento
Ingeniería Eléctrica, Electrónica, Control, Telemática y Química Aplicada a la Ingeniería



