Estudio de la adaptación del stent de una prótesis valvular aórtica mediante simulación numérica

Suárez García, Sofía, López Campos, José Ángel, López García, Irea, Agudo del Río, David, Segade Robleda, Abraham y González Baldonedo, Jacobo(2022) .Estudio de la adaptación del stent de una prótesis valvular aórtica mediante simulación numérica. XV Congreso Iberoamericano de Ingeniería Mecánica.En: Universidad Politécnica de Madrid. (2022-11-22)

Ficheros (Some files may be inaccessible until you login with your e-spacio credentials)
Nombre Descripción Tipo MIME Size
Abs_236_182312.docx Estudio de la adaptación del stent Click to show the corresponding preview/stream application/vnd.openxmlf... 3.10MB

Título de la Conferencia XV Congreso Iberoamericano de Ingeniería Mecánica
Fecha de inicio de la Conferencia 2022-11-22
Fecha fín de la Conferencia 2022-11-24
Lugar de la Conferencia Universidad Politécnica de Madrid
Fecha de presentación de la Ponencia 2022
Titulo Estudio de la adaptación del stent de una prótesis valvular aórtica mediante simulación numérica
Autor(es) Suárez García, Sofía
López Campos, José Ángel
López García, Irea
Agudo del Río, David
Segade Robleda, Abraham
González Baldonedo, Jacobo
Materia(s) Ingeniería Mecánica
Resumen En el presente trabajo se presenta una metodología para el estudio de la capacidad de adaptación de la estructura soporte de una prótesis valvular biológica transcateter a la anatomía particular del paciente. Las implantaciones de válvulas bioprotésicas fabricadas con pericardio bobino o porcino son prácticas habituales en pacientes con estenosis valvular y que no pueden ser intervenidos por ser población con un riesgo elevado. Una fase fundamental y que está altamente relacionada con la durabilidad del dispositivo es la adaptación de la estructura a la raíz aórtica del paciente. Una adaptación defectuosa puede conducir a reducciones severas en la vida útil del dispositivo y, además, provocar pérdidas de estanqueidad que se traducirán en reflujos de sangre hacia el ventrículo. Para estudiar la adaptación de la estructura soporte se establece un procedimiento mediante el cual, a partir de la anatomía de cada paciente extraída mediante imagen médica se construye un modelo de elementos finitos de su raíz aórtica. Este modelo se complementa con el modelo de elementos finitos generado para la estructura soporte de la válvula bioprotésica (stent) previamente validado. Se genera entonces un modelo completo que evalúa la interacción entre la arteria y el stent y que permite evaluar aspectos tales como las áreas de contacto entre ambos y la tensión y deformación en estos componentes.
Abstract In present work a methodology is presented to perform a study about the way in which the supporting structure of a TAV (Transcatheter Aortic Valve) suits into a particular anatomy of a specific patient. Bioprothestic valves made with bovine or porcine pericardium are often implanted in patients who shows valve stenosis and who are not suitable to other more invasive methods, due to that they frequently are high risk population. A fundamental phase and highly related to durability of such devices is the adjustment between the valve and the aortic root of the specific patient. A deficient adjustment could lead to meaningful decreasing in lifespan of the device and, in addition, it could lead to defects in sealing that will probably evolve to backflow of blood into the ventricle. In order to study the adjustment of the stent, a procedure is stablished, therefore, according to such procedure, the anatomy of each patient is extracted taking the data from medical images. Such images in DICOM medical format are used to build a finite element model of aortic root. This model is completed by including the stent model that was previously validated. A full model is generated to evaluate interaction between artery and stent and it allows to evaluate some features such as contact areas or stress and strain in such components. Se genera entonces un modelo completo que evalúa la interacción entre la arteria y el stent y que permite evaluar aspectos tales como las áreas de contacto entre ambos y la tensión y deformación en estos componentes.
Palabra clave TAVI
FEM
biomecánica
simulación computacional
Editor(es) Universidad Nacional de Educación a Distancia (España)
Universidad Politécnica de Madrid. Departamento de Ingeniería Mecánica
Fecha 2022
Formato application/ms-word
Identificador bibliuned:congresoCIBIM-2022UPMEspana-Ssuarez
https://doi.org/10.5944/bicim2022.164
http://e-spacio.uned.es/fez/view/bibliuned:congresoCIBIM-2022UPMEspana-Ssuarez
Idioma spa
Versión de la publicación publishedVersion
Nivel de acceso y licencia http://creativecommons.org/licenses/by-nc-nd/4.0
info:eu-repo/semantics/openAccess
Tipo de recurso conferenceObject
Tipo de acceso Acceso abierto

 
Versiones
Versión Tipo de filtro
Contador de citas: Google Scholar Search Google Scholar
Estadísticas de acceso: 160 Visitas, 26 Descargas  -  Estadísticas en detalle